The selling company should also have a good reagent
support. It is better to have the total system from one
company. This makes sure that the company personnel
also understand the exact application of the unit rather
than only the engineering aspects.
Broad based classification of analyzers can fall under the
Serum sample-reagent mixture is done manually outside
the unit and fed manually. The unit performs/monitors/
evaluates the chemical reaction and gives the result on
display and/or printer. The setting of the unit is normally
automatic as regards wavelength, temperature, etc.
Serum sample-reagent mixing is normally automatic and
the mix is fed automatically to the analyzer. The analyzer
performs the same function as a semiauto analyzer unit.
Here a batch of a particular chemistry test (say, glucose,
urea) can be set up and performed automatically. One
reagent is stored on the machine at a time.
On the machine more than one reagent is stored. Patient
samples are kept on the machine. The computer is
programed to carry out selected tests on individual samples.
Any particular sample and reagent can be selected, mixed,
incubated and monitored as per the program. The patient
report is fully compiled by the unit and printed out.
(Courtesy: Tulip Group of Companies)
The clin check plus is a clinical chemistry/biochemistry
analyzer, designed for a precise and fast execution of
almost all-clinical chemistry analysis. Automatic selection
of filters and temperature controller is all managed by the
microprocessor. The CCP is a fully open machine with
40 locations. Following arrays can be performed on the
Excellent features; with only 4 operating keys; very simple
to handle; reads OD up to 2.0 A; In-built incubation
(2 positions); RS 232 port makes compatible with PC
Communication; which can also handle data from
machine to PC. It is a lightweight and sturdy machine with
less breakdown and low maintenance cost.
The machine is ideally suited for growing or nascent
¾ User friendly, fully open system with 40 programable
¾ Only 4 operating keys- very simple to handle
¾ Reads OD up to 2.0 A large working range
¾ Two inbuilt incubator positions
¾ RS 232 software support for external serial port printer
¾ Data handling software available
Light source 2 W long-life tungsten incandescent lamp
Filters 340, 405, 505, 546, 630 nm; 8 nm
Temperature accuracy ± 0.2 ° C
Stabilisation period 10–20 minutes
Thermostatic unit Two places for square or
Measuring range 0 to + 2000 OD
Photometric linearity ± 2% from 0 to 1700 OD
Photometric accuracy ± 2% from 0 to 1700 OD
Drift Lower than 0.005 OD per hour
Measure method End point, kinetics, fixed-time,
Display 32 characters, liquid crystals,
Serial Output Rs. 232 standard
Power Supply 220 V, 50 Hz., 117V, 60Hz., 40 VA
(Courtesy: Tulip Group of Companies)
A typical clinical chemistry semi-autoanalyzer with
unmatched features designed for Indian laboratories.
Quality at par and performance as per international
standards which can perform. EP/KIN/FXT/MSD with ABS
The machine uses both flow cell (18 µL) and cuvettes
(semi-micro cuvettes) also ensuring less carry over effect
and less breakdown period of the machine. It covers the
entire range of spectrum for measurements (340–700
nm). Automatic selection of filters and is managed by
microprocessors with in-built 10 position incubator which
is regulated by Peltier heat pumps.
It is very simple to handle and is user friendly as its
operation and programing of machine is done by keyboard
and set of instruction displayed on the display. All results are
interpreted by units and also graphs are available for KIN/
MSD. Also has dynamic display (real time display of OD) for
KIN and also reagent blank OD (save)-ensures minimum
consumption of reagents. Any errors or malfunction in the
machine is denoted on the display or printout.
The machine is capable of storing 500 results in memory
and is able to retrieve also for later use. Also has inbuilt 20
column thermal printer (optional). A built in QC program
which validates the overall performance of system. Gives
mean, SD, CV and Levey-Jennings chart. Computer
compatibility with RS 232 port, which also supports data
¾ User friendly, fully open system with 90 programable
¾ 18 µL flowcell minimizes reagent consumption and
¾ Reads OD up to 2.5 A-large working range
¾ Built in 24 column graphic thermal printer
¾ 10 position incubator at 25°, 30°, 37°C
¾ Incubated flowcell resting chamber
¾ Stores 500 test results in memory
¾ Built in software for QC program with mean, SD, CV
Technical Features of Screenmaster 3000
Operating modes Absorbance, end point,
fixed-time, kinetic and multistandard and tests
Aspiration Peristaltic pump with programable intake volume
Filters 340-405-505-546-578-630 nm
Reagents volumes in 1 mL (min) for macro cuvette,
Measuring range from – 200 to + 2500 OD units
Photometric linearity ± 2% from 0 to 2000 OD units
Incubator 10 positions at 25/30/37°C +
Printer built-in graphic printer with
Power supply 220 V, 50 Hz or 110 V, 60 Hz
(Courtesy: Tulip Group of Companies)
Unique and the only semi-autoanalyzer with True Elisa
reader available in Indian market.
The machine is capable of performing routine
biochemistry test as well as ELISA tests in a single machine,